Loop Installers Information
Basic hints
-
-
Our amplifiers
coverage area are specified to generate
the
peaks (0 dB & 400 mA/m) specified by
the standard. They cannot be compared with
amplifiers specified for only 100 mA/m (16!
times lower power)!
-
Use the cable
suggested for the chosen amplifier. In preplanning
stage, not knowing the exact amplifier, use
a twin-cable (makes it possible to choose
between
one/two or parallel turn loop configuration).
-
Type of wire:
No special isolation demands, ordinary speaker
cables are excellent. Just check the cable
area according to the specification.
-
Select amplifier
using table below.
Please Note!
The amplifiers
maximum coverage area is measured in a free
field situation. In reality (with metallic
objects, like reinforced concrete) the coverage
can be reduced by approximately 20-50%.
-
Follow the installation
manual, take a special look on how to set
the input sensitivity level with the AGC-system.
-
Do not use dynamic
microphones, as this gives an increased risk for magnetic
self-oscillation.
Please
refer to UniVox Knowledge for detailed information
|
|